Stay updated with the most recent editions of ODT Magazine, featuring comprehensive coverage of the latest innovations and developments.
Access the full digital version of ODT Magazine, complete with interactive features and enhanced content for a seamless reading experience.
Join the ODT community! Subscribe to receive the latest industry news and insights delivered directly to your mailbox.
Discover how 3D printing and additive manufacturing are revolutionizing orthopedic device design and production processes.
Learn about contract manufacturing solutions in the orthopedic sector, emphasizing quality, compliance, and operational excellence.
Stay informed on the latest research and development trends in orthopedic device design, driving innovation and patient care improvements.
Explore the latest advancements in surgical instruments and technologies that enhance precision and outcomes in orthopedic procedures.
Discover cutting-edge machining and laser processing techniques that improve the quality and performance of orthopedic devices.
Learn about the innovative materials shaping orthopedic devices, focusing on performance, biocompatibility, and regulatory compliance.
Stay updated on advanced molding techniques for producing high-quality orthopedic components that meet industry standards.
Explore best practices for packaging and sterilization methods that ensure the safety and efficacy of orthopedic devices.
Discover the role of software solutions in enhancing orthopedic device design, functionality, patient management, and regulatory compliance.
Learn about essential testing methods and standards that ensure the safety, reliability, and effectiveness of orthopedic devices.
Stay ahead with real-time updates on significant news impacting the orthopedic device sector.
Access unique content and insights not available in the print edition of ODT Magazine, offering deeper dives into important topics.
Explore feature articles that provide in-depth analysis on specific topics within orthopedic design and technology.
Gain insights from industry experts through regular columns addressing critical challenges and innovations in orthopedics.
Read the editorial insights on current trends and highlights from the latest issue of ODT Magazine.
Discover leading companies in orthopedic design and technology, showcasing their innovations and contributions to the field.
Explore detailed profiles of companies in the orthopedic device manufacturing sector, highlighting their capabilities and offerings.
Learn about the expertise and resources of leading companies in the orthopedic device manufacturing sector.
Watch informative videos featuring industry leaders discussing trends, technologies, and innovations in orthopedic design.
Enjoy short, engaging videos that provide quick insights and updates on key topics within orthopedics.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in orthopedic technology.
Participate in informative webinars led by industry experts covering various relevant topics in orthopedic design and manufacturing.
Stay informed on the latest press releases and announcements from leading companies in the orthopedic device manufacturing sector.
Access comprehensive eBooks that delve into various topics in orthopedic device manufacturing and innovation.
Highlighting the pioneers and innovators driving advancements in orthopedic technology and patient care.
Explore sponsored articles and insights from leading companies in the orthopedic industry.
Read in-depth whitepapers that examine key issues, trends, and research findings in orthopedic design and technology.
Discover major industry events, trade shows, and conferences focused on orthopedic technology and innovations.
Get real-time updates and insights from major industry shows and exhibitions happening around the world.
Participate in the ODT Forum, addressing orthopedic design and manufacturing technology trends, innovations, and industry challenges.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical device technology.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Explore advertising opportunities with ODT to connect with a targeted audience of orthopedic professionals.
Review our editorial guidelines for submissions and contributions to ODT.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of odtmag.com.
What are you searching for?
One-year results demonstrate early and marked improvements in pain, disability and quality of life.
August 26, 2015
By: Michael Barbella
The clinical data for SI-Bone Inc.’s iFuse Implant System are slowly coming to pass, and the results appear very promising. The company recently announced the publication of one-year results from two separate prospective multicenter clinical trials as well as the publication of a systematic review of 18 MIS SI joint fusion studies.
“Collectively, these three recent publications significantly strengthen the more than 20 clinical papers already published on iFuse and further solidify our clinical evidence foundation supporting MIS SI joint surgery using SI-BONE’s unique triangular implants,” President/CEI Jeffrey Dunn said in a news release.
The first clinical trial publication is of INSITE (Investigation of Sacroiliac Fusion Treatment), a prospective multicenter randomized controlled trial (RCT) that included 148 subjects treated at 19 centers. One-year results from INSITE were published in the journal Neurosurgery1; subjects were randomized in a 2:1 ratio to either immediate SI joint fusion with iFuse (102 subjects) or non-surgical management (NSM, 46 subjects).
Subjects surgically treated with iFuse had a mean 52-point reduction in SI joint pain at six months on the 0-100 Visual Analog Scale (VAS) versus a mean 12.2-point decrease in the NSM group. Pain relief was sustained at 12 months in the surgical group with a mean 54.2-point reduction from the baseline VAS measurement. The study design allowed subjects in the NSM group to cross over and have surgery after six months and 79.5 percent of the NSM group elected to have the iFuse procedure as of June 30, 2015. NSM group subjects who elected to cross over to iFuse surgery after six months had pain reduction similar to that seen in subjects originally assigned to iFuse surgery. The study also included Oswestry Disability Index (ODI), a measure of disability due to back pain, where a score of 0 indicates no disability and scores greater than 60 indicate severe disability. At baseline, all subjects showed a high degree of disability (mean 56.8). Subjects assigned to iFuse had a mean 27.4-point reduction in ODI at six months while subjects assigned to NSM had only a mean 4.6-point decrease (p < 0.0001 for difference between groups). Reduction in disability was sustained at twelve months in the iFuse group with a mean 29.3-point reduction from baseline. In addition, subjects who elected to cross over after six months to have the iFuse procedure had similar disability reduction as the subjects originally assigned to SI joint fusion with iFuse.
At 12 months, taking into account responses due solely to the assigned treatment, clinically important improvements in VAS SI joint pain were seen in 81.6 percent of SI joint fusion subjects but only 12.5 percent of NSM subjects (p < 0.0001 for difference). Similarly, for ODI scores, clinically important improvements were observed in 72.4 percent vs. 10 percent, respectively.
“Surgery vs. non-surgery studies are difficult to execute. INSITE’s design and execution in preventing early crossover has provided significant, high quality, Level 1 evidence to the existing body of literature demonstrating that, for patients with certain SI joint disorders, SI joint fusion with triangular porous coated titanium implants can meaningfully improve pain, function and quality of life compared to non-surgical management,” noted David Polly, M.D., lead author of the paper. “This study shows that significant improvements in pain, disability and quality of life achieved at six months were sustained at 12 months and that subjects who crossed over to iFuse treatment did nearly as well as those originally assigned to iFuse.”
The second multicenter clinical study, called SIFI (Sacroiliac Joint Fusion with iFuse Implant System), was a prospective multicenter single-arm clinical trial of SI joint fusion using iFuse in a patient population with the same enrollment criteria as INSITE. The study included 172 subjects at 26 U.S. centers and was published in Global Spine Journal2.
Twelve-month postoperative follow-up was available in 157 of 172 initially enrolled subjects (91 percent). By six months, 81 percent of subjects met the study’s definition for treatment success; by 12 months, the success rate was 80 percent. Mean SI joint pain improved from 79.8 at baseline to 30 and 30.4 at six and 12 months respectively (mean improvements of 49.9 and 49.1 points, p < 0.0001 each). Mean ODI improved from 55.2 at baseline to 32.5 and 31.4 at six and 12 months (improvements of 22.7 and 23.9 points, p < 0.0001 each). SF-36 physical component summary (PCS), a quality of life measurement summarizing overall physical health, improved from 31.7 at baseline to 40.2 and 40.3 at six and 12 months (p < 0.0001). At six and 12 months, 94 percent and 87 percent of subjects, respectively, were somewhat or very satisfied and 92 percent and 91 percent, respectively, stated they would have the procedure again. Two subjects underwent revision for immediate postoperative radiculopathy due to implant malposition and two patients underwent late revision surgery.
“The one-year results from the SIFI study have shown durable improvements in pain, disability, and quality of life with the iFuse procedure. This paper adds important, high quality clinical evidence to the more than two-dozen existing publications that support the safety and effectiveness of the iFuse procedure,” said Brad Duhon, M.D., lead author of the SIFI one-year publication.
One-year results from both INSITE and SIFI demonstrate early and marked improvements in pain, disability and quality of life that were maintained to 12 months in more than 250 subjects.
The third publication was published in the International Journal of Spine Surgery (IJSS)3. Study authors used PRISMA, a published standard for systematic reviews, to perform a systematic review and meta-analysis of published literature reporting clinical outcomes on subjects who underwent MIS SI joint fusion using a lateral transarticular approach. A total of 18 articles met the inclusion criteria and after accounting for overlapping cohorts, 12 unique cohorts from four countries were extracted for a total of 432 subjects. Of the 12 unique cohorts, 10 were iFuse cohorts that included a total of 368 treated subjects. For the 12 unique cohorts, random effects meta-analysis (RMA) mean (range) procedure time was 59 minutes (27-78), estimated blood loss was 36.9 cc (10-70) and hospital length of stay (LOS) was 1.7 days (range 0-7). The RMA mean pain score dropped by 5.2 points at six months and 5.3 points at 12 months (baseline score of 8.1, 12-month score of 2.7), and a 24-month score of 2.0. ODI decreased by 31 points at 12 months (baseline score of 56.2, 6-month score of 30.7, and 12-month score of 25.1). Two studies in the review had long-term (4.5 and five years) follow-up with consistent results.
These results demonstrate that MIS SI joint fusion using a lateral transarticular approach provides consistent and clinically important improvements in pain and associated disability that is maintained out to five years, SI-Bone officials said. Changes seen in the iFuse cohorts (which represented 85 percent of treated subjects) were larger than those seen in the cohorts in which hollow modular anchor screws were used. Furthermore, the minimally invasive characteristics of this procedure were confirmed as evidenced by minimal blood loss, a short operative time and brief length of stay.
Clinical publications have identified the SI joint as a pain generator in 15 percent to 30 percent of low back pain patients.4-7 In addition, the prevalence of SI joint pain in post-lumbar fusion, so called “failed back surgery” patients, has been shown to be up to 43 percent.8 Of these patients with SI joint pain, some may have degenerative sacroiliitis or SI joint disruptions. Initial treatment options for patients with SI joint disorders typically involve non-surgical management and, when non-surgical management of the SI joint fails, surgical options such as the iFuse procedure may be considered.
SI-Bone received U.S. Food and Drug Administration 510(k) clearance in November 2008 to market its iFuse Implant System. The CE mark for European commercialization was obtained in November 2010.
The iFuse Implant System is a minimally invasive surgical option that uses titanium implants coated with a porous, titanium plasma spray (TPS) that acts as an interference surface, designed to help decrease implant motion, provide immediate fixation and allow for biological fixation to support long term fusion. The iFuse Implant System is intended for sacroiliac fusion for conditions including sacroiliac joint dysfunction that is a direct result of sacroiliac joint disruption and degenerative sacroiliitis. This includes conditions whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than six months.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !